mrfseg.pl
MRF-based tissue segmentation pipeline
mrfseg.pl <input_t1.mnc> <output.mask> [options]
DESCRIPTION
mrfseg.pl is a Perl wrapper that runs an MRF (Markov Random Field) based tissue segmentation pipeline on a T1-weighted MRI volume. The pipeline first estimates tissue intensity distributions using gamixture (Gaussian mixture modelling), then applies mrfseg to perform spatially regularized classification. The result is a discrete tissue label mask.
An atlas specification can be supplied to provide tissue priors. A brain mask can be provided to restrict the segmentation to the brain region. A low-resolution mode is available for faster processing at reduced spatial resolution.
OPTIONS
--verbose- Print progress information during processing.
--clobber- Overwrite existing output files.
--mask <mask.mnc>- Specify a brain mask to restrict the segmentation region. The default value is “default”, which uses the mask provided by the atlas.
--atlas <spec>- Specify an atlas directory or specification file for tissue priors.
--lowres- Run the segmentation at low resolution for faster processing.
EXAMPLES
Segment a T1 volume using default settings:
mrfseg.pl input_t1.mnc output_labels.mnc
Segment with a custom brain mask and verbose output:
mrfseg.pl input_t1.mnc output_labels.mnc --verbose --mask brain_mask.mnc
Segment using a specific atlas and low-resolution mode:
mrfseg.pl input_t1.mnc output_labels.mnc --atlas /path/to/atlas --lowres --clobber
AUTHOR
Vladimir S. Fonov. McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University.
COPYRIGHTS
Copyright (C) Vladimir S. Fonov and McGill University. Licensed under the terms of the GNU General Public License version 3 or later.
SEE ALSO
classify(1), em_classify(1), pipeline_classify.pl(1)